FAQs - IDEC SmartRelay

Display Function

What's the limitation on the Text Message function block?

Up to 10 text message function blocks can be used. Please see Page 182 of the Instruction Manual. Â

Last Updated: 04/15/04


Is it possible to monitor the Up/Down counter's preset and current values?

Yes, it is possible to monitor the counter's present and current values if using the SmartRelay with LCD display. By changing the SmartRelay's setting to parameter mode, the following parameters can be monitored:

  • Timer's preset and current value.
  • Counter's preset and current value
  • Present value of the run time counter
  • Analog preset and current values

Last Updated: 04/15/04


Is it possible to display the number of function blocks being used?

Yes. WindLGC can be used to display the number of blocks being used. While Info Window is open (press F4 on keyboard to open) press F2 on keyboard and a message on Info Window will display how many function blocks are being used. IDEC SmartRelay with LCD panel, it can be found in the program edit mode.

Last Updated: 04/15/04